Modular and adaptable type ll water delivery. Grows with your lab. Flexible. Reliable. Unmatched.
Features
Deionization The Reverse Osmosis feed contains optimized resin mixes to maximize consumables capacity.
Simplicity Simple to install, operate and maintain with a clear indication of water purity.
Economical Optional CO2 removal from the purified water (post-RO) increases the life of downstream consumables. Option to reduce water consumption for low hardness feed waters.
Modular Multiple PURELAB Chorus 2 units can feed into one reservoir and systems can be expanded post-installation. As such, the cost of future upgrades is minimized. Duplex systems also guarantee maximum uptime.
Ideally suited for: Stills Replacement, Stills Replacement, Buffer Preparation, pH solution Preparation, Washing / Rinsing, Autoclaves, General Chemistry, Hydroponics, Steam Generators, Sterilizer Feed, Feed to Type I polishers.
Simple, elegant water dispenser and deionization system for your distribution.
Customized settings Be in control of your PURELAB flex by customizing the settings to suit your application.
Simplicity Simple to install, operate and maintain with prioritized information displayed at all times (system status, alarm) for absolute confidence as you dispense.
Data capture Download all of the data to USB for system performance validation and software updates.
Easy to Use Ergonomic design with features including auto volumetric dispense and height adjustability.
Space Saving Space-saving and compact dispensers can be placed on the bench or wall-mounted.
Ideally suited for: Dispensing, With DI pack: General lab, Applications requiring type 2 water
Precise, reliable and safe. Memmert heating ovens and drying ovens are used in research, industry and medicine for a variety of applications: heating, drying, tempering, testing, ageing, sterilisation, burn-in test, annealing, curing, polymerisation, vulcanisation, heated storage and conditioning.
32 litre or 1060 litre chamber volume? Simple drying tasks or high demand for programming and documentation? A Memmert heating oven and drying oven suits any application thanks to the wealth of communication interfaces, configurations and options. It meets the strict requirements of DIN 12880:2007-05 and has a maximum of safety functions.
In developing its temperature control appliances and heating baths, Memmert pursues a primary goal: a controlled atmosphere. And this has been the case since 1947, when the first Memmert hot air steriliser left our company. A user of a Memmert water bath can also rely on reliability, user-friendliness and an excellent price-performance ratio.It is the precise control technology that ensures optimum temperature uniformity and stability in a Memmert water bath. At least the three-stage safety system guarantees optimum safety in every temperature control bath.
Precise, energy-efficient and safe. Even minimal temperature deviations can cause an experiment or cultivation in an incubator to fail. Therefore heating and control in a Memmert incubator are perfectly matched to avoid dangerous temperature overshoots.Even during the heating phase, a Memmert incubator keeps the set parameters within the tightest tolerances throughout the interior. It meets the strict requirements of DIN 12880:2007-05 and is equipped with absolutely reliable safety functions.
Neogen®'s new AccuPoint® Advanced Next Generation (NG) is a complete sanitation monitoring system comprising a handheld instrument, innovative samplers, and data manager software, designed to verify your cleaning processes by measuring adenosine triphosphate (ATP). After cleaning your environment, measuring the amount of ATP present on a surface or in liquids allows you to verify your cleaning processes have been effective.
Solutions Built to Enhance Your Allergen Control Plan. F&S Scientific offers both quantitative ELISA and qualitative lateral flow diagnostic testing solutions for rapid allergen detection. These solutions are designed to detect low levels of allergen in a wide variety of sample types and be used as part of your allergen control plan.
Neogen’s new Soleris® Next Generation (NG) can rapidly detect various microorganisms that can threaten the safety and quality of food and other consumer products. For example, Soleris NG can detect and enumerate yeast and mould in a sample in only 48 hours, as compared to the three to five days needed for traditional methods, and detects Alicyclobacillus, a bacterium of particular concern to the fruit juice industry, in only 48 hours, compared to the five days of other ways.
We provide you with a wide range of qualitative and quantitative test kits to cover all of your testing needs. We also offer full-service mycotoxin support, including remote training with LabLive, troubleshooting assistance, procedure pages, Proficiency Testing programs, 24/7 global customer assistance, and ISO-accredited labs — all to enhance your mycotoxin testing program.
The use of UV transilluminators for the detection of DNA or RNA in agarose gels, is still very common, although we know quite well that the shorter the wavelength is, the more the DNA will be damaged quickly, which is dangerous especially if the separated DNA should be used in downstream experiments like cloning or sequencing. Just seconds of UV light is enough to reduce the cloning efficiency significantly.
In contrast to UV instruments, the new innovative LED technology uses a much higher wavelength, which means energy-less light. This will lead to the fact that the nucleic acids are not damaged but sometimes sensitivity is lower as compared to UV light. Furthermore, regular BLUE LED technology is working well with green dyes but couldn’t be recommended with red dyes like Ethidium Bromide, because the longer wavelength is favourable for green dyes but not for red components.
A FLOQSwab® is a flocked swab that consists of a moulded plastic applicator stick with a variable size and shape tip. The tip of the applicator is coated with short Nylon® fibres that are arranged in a perpendicular fashion. FLOQSwabs® have no internal core to trap the specimen.
The flocked swab tip is coated perpendicularly and sprayed on Nylon® fibres. This coating creates a thin absorbent layer that allows for quick sample uptake and elution of more than 90% of the sample. Compare this elution to traditional spun swabs that trap the majority of the specimen in the 'mattress' structure, making it unavailable for testing, and it's easy to see why FLOQSwabs® are used by more and more laboratories and medical institutions around the world.
F&S Scientific is a leading provider of laboratory and field testing solutions in East Africa. We serve
customers in Healthcare, Industries, Research and Academia