Liquid handling systems from F&S Scientific are used wherever accuracy, precision, and absolute reliability are important. With our pipetting and dispensing tools, we strive to simplify cumbersome lab work and make it as safe and efficient as possible so you can concentrate on and accelerate your research.
F&S Scientific consumables with unique features make everyday routines faster, easier, and more reliable. Due to the avoidance of any slip agents, plasticizers, and biocides during manufacturing, the risk of chemical leaching into the sample is minimized. The availability of different purity grades is tailored to the various requirements in laboratories.
Made of the highest quality materials, with superior design and precision fabrication, we guarantee our lab shakers will provide worry-free operation for many years to come.
F&S Scientific LTD offers a choice of preventive maintenance services and service agreement options for consistent instrument performance and confidence in safety.
As the epitome of laboratory excellence and consistency, F&S Scientific incubators provide users with exceptional culture control. For best-in-class performance, durability and time savings, choose F&S Scientific Incubators.
Ideal for professional flue gas analysis and industrial emission measurement: the Testo 350 flue gas analyzer performs a variety of measuring and analysis tasks, impresses over the long term thanks to its heavy-duty industrial design and is also suitable for complex data acquisition.
testo 350 Analysis Box is just as easy to use when not positioned at the measurement site
Internal memory for receiving measurement data from the Analysis Box
Large graphic colour display, robust, industrial-type housing
A visual or odour check is not sufficient to verify whether the quality of the cooking oil is still good. Chain restaurateurs with the testo 270 cooking oil tester only need to change the cooking oil once critical TPM values are reached. This saves them from changing the cooking oil more frequently than is necessary, enabling them to also benefit from the associated cost savings.
Capacitive oil sensor from Testo, together with its needs-based design, make it possible to take measurements in hot oil (user is protected from the heat of the deep fat fryer)
IP 65: protected against water jets without a protective cover
Clear, visual alarm indication via highly-visible alarm backlight in traffic light colours
Washable case for hygienically stowing away at the application site
Instruments for measuring the oxidation stability of biodiesel and its blends, natural oils/fats and fat-containing foodstuffs or the PVC thermostability. We offer three dedicated stability measurement instruments for stability measurement: the Rancimat for the assessment of the induction time or oxidation stability index (OSI) of fat-containing foodstuffs, cosmetics, and natural fats and oils; the Biodiesel Rancimat for oxidation stability testing of biodiesel; and the PVC Thermomat for thermal stability testing of polyvinyl chloride (PVC) and other chlorine-containing polymers by means of the dehydrochlorination test (DHC).
KF titrators and accessories for volumetric and coulometric water content determination in liquid, solid, or gaseous samples. Get the complete range from compact benchtop solutions to modular automated systems including accessories and software for volumetric and coulometric Karl Fischer titration from one supplier.
Eco Titrator is the economic titrator for all standard potentiometric titration applications. Its intuitive touch display and the direct keys for controlling the stirrer speed enable everyone at your lab to perform a titration.
The use of UV transilluminators for the detection of DNA or RNA in agarose gels, is still very common, although we know quite well that the shorter the wavelength is, the more the DNA will be damaged quickly, which is dangerous especially if the separated DNA should be used in downstream experiments like cloning or sequencing. Just seconds of UV light is enough to reduce the cloning efficiency significantly.
In contrast to UV instruments, the new innovative LED technology uses a much higher wavelength, which means energy-less light. This will lead to the fact that the nucleic acids are not damaged but sometimes sensitivity is lower as compared to UV light. Furthermore, regular BLUE LED technology is working well with green dyes but couldn’t be recommended with red dyes like Ethidium Bromide, because the longer wavelength is favourable for green dyes but not for red components.
Phosphate-buffered saline or PBS buffer is a water-based salt solution widely used in cell culture applications, e.g. for maintenance of pH, dilution of substances, or rinsing of cell containers.
Also known as Dulbecco's Phosphate-Buffered Saline (DPBS), PBS is non-toxic and provides cells with water and inorganic ions, which are necessary for cell metabolism. The osmolarity and ion concentrations of PBS solutions are meant to mimic the isotonic milieu of the human body.
This formulation of PBS comes without Ca & Mg and without Phenol Red. The concentration of the solution is 10X.
A FLOQSwab® is a flocked swab that consists of a moulded plastic applicator stick with a variable size and shape tip. The tip of the applicator is coated with short Nylon® fibres that are arranged in a perpendicular fashion. FLOQSwabs® have no internal core to trap the specimen.
The flocked swab tip is coated perpendicularly and sprayed on Nylon® fibres. This coating creates a thin absorbent layer that allows for quick sample uptake and elution of more than 90% of the sample. Compare this elution to traditional spun swabs that trap the majority of the specimen in the 'mattress' structure, making it unavailable for testing, and it's easy to see why FLOQSwabs® are used by more and more laboratories and medical institutions around the world.
F&S Scientific is a leading provider of laboratory and field testing solutions in East Africa. We serve
customers in Healthcare, Industries, Research and Academia