Modular and adaptable type ll water delivery. Grows with your lab. Flexible. Reliable. Unmatched.
Features
Deionization The Reverse Osmosis feed contains optimized resin mixes to maximize consumables capacity.
Simplicity Simple to install, operate and maintain with a clear indication of water purity.
Economical Optional CO2 removal from the purified water (post-RO) increases the life of downstream consumables. Option to reduce water consumption for low hardness feed waters.
Modular Multiple PURELAB Chorus 2 units can feed into one reservoir and systems can be expanded post-installation. As such, the cost of future upgrades is minimized. Duplex systems also guarantee maximum uptime.
Ideally suited for: Stills Replacement, Stills Replacement, Buffer Preparation, pH solution Preparation, Washing / Rinsing, Autoclaves, General Chemistry, Hydroponics, Steam Generators, Sterilizer Feed, Feed to Type I polishers.
Simple, elegant water dispenser and deionization system for your distribution.
Customized settings Be in control of your PURELAB flex by customizing the settings to suit your application.
Simplicity Simple to install, operate and maintain with prioritized information displayed at all times (system status, alarm) for absolute confidence as you dispense.
Data capture Download all of the data to USB for system performance validation and software updates.
Easy to Use Ergonomic design with features including auto volumetric dispense and height adjustability.
Space Saving Space-saving and compact dispensers can be placed on the bench or wall-mounted.
Ideally suited for: Dispensing, With DI pack: General lab, Applications requiring type 2 water
Precise, reliable and safe. Memmert heating ovens and drying ovens are used in research, industry and medicine for a variety of applications: heating, drying, tempering, testing, ageing, sterilisation, burn-in test, annealing, curing, polymerisation, vulcanisation, heated storage and conditioning.
32 litre or 1060 litre chamber volume? Simple drying tasks or high demand for programming and documentation? A Memmert heating oven and drying oven suits any application thanks to the wealth of communication interfaces, configurations and options. It meets the strict requirements of DIN 12880:2007-05 and has a maximum of safety functions.
In developing its temperature control appliances and heating baths, Memmert pursues a primary goal: a controlled atmosphere. And this has been the case since 1947, when the first Memmert hot air steriliser left our company. A user of a Memmert water bath can also rely on reliability, user-friendliness and an excellent price-performance ratio.It is the precise control technology that ensures optimum temperature uniformity and stability in a Memmert water bath. At least the three-stage safety system guarantees optimum safety in every temperature control bath.
Precise, energy-efficient and safe. Even minimal temperature deviations can cause an experiment or cultivation in an incubator to fail. Therefore heating and control in a Memmert incubator are perfectly matched to avoid dangerous temperature overshoots.Even during the heating phase, a Memmert incubator keeps the set parameters within the tightest tolerances throughout the interior. It meets the strict requirements of DIN 12880:2007-05 and is equipped with absolutely reliable safety functions.
Instruments for trace analysis of metals and other electrochemically active substances with voltammetry, polarography, and CVS i.e Professional CVS, Professional VA and Portable VA Analyzer.
Instruments for measuring the oxidation stability of biodiesel and its blends, natural oils/fats and fat-containing foodstuffs or the PVC thermostability. We offer three dedicated stability measurement instruments for stability measurement: the Rancimat for the assessment of the induction time or oxidation stability index (OSI) of fat-containing foodstuffs, cosmetics, and natural fats and oils; the Biodiesel Rancimat for oxidation stability testing of biodiesel; and the PVC Thermomat for thermal stability testing of polyvinyl chloride (PVC) and other chlorine-containing polymers by means of the dehydrochlorination test (DHC).
Advanced process analyzers for industrial inline, online, and atline analysis: petrochemical, energy, semiconductor, metal, paper, mining, and (waste)water applications.
KF titrators and accessories for volumetric and coulometric water content determination in liquid, solid, or gaseous samples. Get the complete range from compact benchtop solutions to modular automated systems including accessories and software for volumetric and coulometric Karl Fischer titration from one supplier.
Eco Titrator is the economic titrator for all standard potentiometric titration applications. Its intuitive touch display and the direct keys for controlling the stirrer speed enable everyone at your lab to perform a titration.
F&S Scientific is a leading provider of laboratory and field testing solutions in East Africa. We serve
customers in Healthcare, Industries, Research and Academia