Liquid handling systems from F&S Scientific are used wherever accuracy, precision, and absolute reliability are important. With our pipetting and dispensing tools, we strive to simplify cumbersome lab work and make it as safe and efficient as possible so you can concentrate on and accelerate your research.
F&S Scientific consumables with unique features make everyday routines faster, easier, and more reliable. Due to the avoidance of any slip agents, plasticizers, and biocides during manufacturing, the risk of chemical leaching into the sample is minimized. The availability of different purity grades is tailored to the various requirements in laboratories.
Made of the highest quality materials, with superior design and precision fabrication, we guarantee our lab shakers will provide worry-free operation for many years to come.
F&S Scientific LTD offers a choice of preventive maintenance services and service agreement options for consistent instrument performance and confidence in safety.
As the epitome of laboratory excellence and consistency, F&S Scientific incubators provide users with exceptional culture control. For best-in-class performance, durability and time savings, choose F&S Scientific Incubators.
Ideal for professional flue gas analysis and industrial emission measurement: the Testo 350 flue gas analyzer performs a variety of measuring and analysis tasks, impresses over the long term thanks to its heavy-duty industrial design and is also suitable for complex data acquisition.
testo 350 Analysis Box is just as easy to use when not positioned at the measurement site
Internal memory for receiving measurement data from the Analysis Box
Large graphic colour display, robust, industrial-type housing
Modular and adaptable type ll water delivery. Grows with your lab. Flexible. Reliable. Unmatched.
Features
Deionization The Reverse Osmosis feed contains optimized resin mixes to maximize consumables capacity.
Simplicity Simple to install, operate and maintain with a clear indication of water purity.
Economical Optional CO2 removal from the purified water (post-RO) increases the life of downstream consumables. Option to reduce water consumption for low hardness feed waters.
Modular Multiple PURELAB Chorus 2 units can feed into one reservoir and systems can be expanded post-installation. As such, the cost of future upgrades is minimized. Duplex systems also guarantee maximum uptime.
Ideally suited for: Stills Replacement, Stills Replacement, Buffer Preparation, pH solution Preparation, Washing / Rinsing, Autoclaves, General Chemistry, Hydroponics, Steam Generators, Sterilizer Feed, Feed to Type I polishers.
Simple, elegant water dispenser and deionization system for your distribution.
Customized settings Be in control of your PURELAB flex by customizing the settings to suit your application.
Simplicity Simple to install, operate and maintain with prioritized information displayed at all times (system status, alarm) for absolute confidence as you dispense.
Data capture Download all of the data to USB for system performance validation and software updates.
Easy to Use Ergonomic design with features including auto volumetric dispense and height adjustability.
Space Saving Space-saving and compact dispensers can be placed on the bench or wall-mounted.
Ideally suited for: Dispensing, With DI pack: General lab, Applications requiring type 2 water
These options enable a top-loading sterilizer to be tailored to the needs of the customer by speeding up cooling, dealing with liquids, and porous-type loads and allowing a wider range of items to be efficiently processed
Instruments for trace analysis of metals and other electrochemically active substances with voltammetry, polarography, and CVS i.e Professional CVS, Professional VA and Portable VA Analyzer.
Instruments for measuring the oxidation stability of biodiesel and its blends, natural oils/fats and fat-containing foodstuffs or the PVC thermostability. We offer three dedicated stability measurement instruments for stability measurement: the Rancimat for the assessment of the induction time or oxidation stability index (OSI) of fat-containing foodstuffs, cosmetics, and natural fats and oils; the Biodiesel Rancimat for oxidation stability testing of biodiesel; and the PVC Thermomat for thermal stability testing of polyvinyl chloride (PVC) and other chlorine-containing polymers by means of the dehydrochlorination test (DHC).
Potentiostat/galvanostat instruments, modular extensions, software, and accessories for electrochemical research. Our portfolio of electrochemical measuring instruments includes compact to modular and single-channel to multi-channel potentiostats/galvanostats. Use the filters to refine your search and find the perfect instrument for you.
Our range of ion chromatography (IC) instruments covers cost-effective, compact, and stand-alone options for routine analysis as well as modern, fully automated, and hyphenated systems for advanced applications. Our IC portfolio includes detectors, columns, sample preparation and automation solutions. Use the filters to refine your search and find the perfect ion chromatography system for you.
KF titrators and accessories for volumetric and coulometric water content determination in liquid, solid, or gaseous samples. Get the complete range from compact benchtop solutions to modular automated systems including accessories and software for volumetric and coulometric Karl Fischer titration from one supplier.
The use of UV transilluminators for the detection of DNA or RNA in agarose gels, is still very common, although we know quite well that the shorter the wavelength is, the more the DNA will be damaged quickly, which is dangerous especially if the separated DNA should be used in downstream experiments like cloning or sequencing. Just seconds of UV light is enough to reduce the cloning efficiency significantly.
In contrast to UV instruments, the new innovative LED technology uses a much higher wavelength, which means energy-less light. This will lead to the fact that the nucleic acids are not damaged but sometimes sensitivity is lower as compared to UV light. Furthermore, regular BLUE LED technology is working well with green dyes but couldn’t be recommended with red dyes like Ethidium Bromide, because the longer wavelength is favourable for green dyes but not for red components.
Phosphate-buffered saline or PBS buffer is a water-based salt solution widely used in cell culture applications, e.g. for maintenance of pH, dilution of substances, or rinsing of cell containers.
Also known as Dulbecco's Phosphate-Buffered Saline (DPBS), PBS is non-toxic and provides cells with water and inorganic ions, which are necessary for cell metabolism. The osmolarity and ion concentrations of PBS solutions are meant to mimic the isotonic milieu of the human body.
This formulation of PBS comes without Ca & Mg and without Phenol Red. The concentration of the solution is 10X.
A FLOQSwab® is a flocked swab that consists of a moulded plastic applicator stick with a variable size and shape tip. The tip of the applicator is coated with short Nylon® fibres that are arranged in a perpendicular fashion. FLOQSwabs® have no internal core to trap the specimen.
The flocked swab tip is coated perpendicularly and sprayed on Nylon® fibres. This coating creates a thin absorbent layer that allows for quick sample uptake and elution of more than 90% of the sample. Compare this elution to traditional spun swabs that trap the majority of the specimen in the 'mattress' structure, making it unavailable for testing, and it's easy to see why FLOQSwabs® are used by more and more laboratories and medical institutions around the world.
F&S Scientific is a leading provider of laboratory and field testing solutions in East Africa. We serve
customers in Healthcare, Industries, Research and Academia